Artifact rejection refers to the set of methods used to identify and remove or mitigate artifacts—unwanted fluctuations or distortions—from data so that the underlying signal can be interpreted more reliably. This practice is a standard step in many data-rich disciplines, notably in neuroscience and imaging, as well as in audio, video, and other signal-processing domains. The overarching aim is to preserve genuine, meaningful signal components while discarding or suppressing noise, interference, and non-substantive disturbances.
In fields such as electroencephalography and magnetoencephalography, artifact rejection is essential for interpreting neural activity. The process also appears in functional magnetic resonance imaging and other imaging modalities where motion, physiological processes, and equipment limitations introduce distortions. Beyond neuroscience, artifact rejection plays a role in audio engineering, seismology, and remote sensing, wherever the integrity of a signal is compromised by extraneous sources.
Scope and definitions
- What qualifies as an artifact: Artifacts are signals or data features that do not originate from the phenomenon of interest. Examples include eye-blink and heart-beat activity in EEG/MEG, subject motion in MRI, electrical interference in audio recordings, and instrumental noise in industrial sensing.
- Goals of rejection vs correction: Rejection often means excluding contaminated time segments or channels, while correction aims to estimate and subtract the artifact so that the original signal remains. Some workflows combine both strategies, applying partial corrections with selective rejection to balance data retention against cleanliness.
- Distinction from calibration and normalization: Artifact rejection is distinct from (but complementary to) calibration (titting sensor responses) and normalization (adjusting across datasets). Proper preprocessing typically intertwines these steps to enable reliable analysis.
Techniques
Artifact rejection employs a spectrum of methods, ranging from manual inspection to sophisticated automated algorithms. The choice of technique depends on the data modality, the type of artifact, and the research or application goals.
Manual rejection
- Visual inspection and annotation: Expert reviewers examine data to label contaminated segments or channels for exclusion.
- Pros and cons: Manual methods can be highly accurate for complex or idiosyncratic artifacts but are time-consuming and may introduce subjective bias or inconsistencies across raters.
Automated thresholding and rule-based approaches
- Amplitude and variance thresholds: Segments with unusually large amplitudes or excessive variance are flagged for removal.
- Gradient and slope criteria: Rapid changes in signal value can indicate artifacts, prompting rejection.
- Pros and cons: Automation improves reproducibility and throughput but risks over- or under-rejection if thresholds are not well-tuned to the data.
Regression-based and model-driven approaches
- Regressing out known artifact sources: Physiological signals such as eye movements (EOG) or heart activity (ECG) are recorded and regressed from the data to minimize contamination.
- Regression of motion parameters in imaging: In MRI, head movement estimates are used to account for motion-related variance.
- Pros and cons: These methods preserve some neural or signal content while removing modeled noise, but unmodeled artifacts may persist, and overfitting can remove genuine signal too.
Independent Component Analysis (ICA) and blind source separation
- Decomposing signals into statistically independent components: ICA separates sources that contribute to the observed data, making it possible to identify components corresponding to artifacts (e.g., eye blinks, muscle activity).
- Component selection and removal: Researchers label artifact components based on spatial patterns, time courses, and spectral properties, then remove or attenuate them before reconstructing a cleaned signal.
- Pros and cons: ICA can target complex, non-stationary artifacts, but misclassification of components can remove neural signals or leave residual artifacts. Validation and cross-subject checks are common practices.
Wavelet and time-frequency denoising
- Wavelet transforms and other time-frequency methods: Artifacts can be localized in time and frequency, enabling selective suppression of contaminant features while preserving portions of the signal.
- Pros and cons: Effective for certain transient artifacts but may distort true signal if not carefully tuned.
Motion correction and artifact handling in imaging
- Motion correction: In functional and structural MRI, realignment procedures and slice-timing corrections help mitigate motion-related distortions.
- ICA-based and model-based artifact removal in imaging: Techniques such as ICA-AROMA and related methods identify motion-related components for removal.
- Pros and cons: Imaging artifact strategies aim to preserve spatial information and functional signals while removing noise, but aggressive cleaning can bias estimates of activation or connectivity if artifacts co-vary with genuine signals.
Domain applications
- In neuroscience, artifact rejection is crucial for interpreting event-related potentials, oscillatory activity, and functional measures in EEG/MEG and fMRI. The balance between clean data and retention of neural information is central to study design and statistical inference.
- In audio and music processing, artifact rejection helps remove hum, clipping, or microphone noise without harming the desired sound characteristics.
- In seismology and geophysics, removing cultural noise, instrument drift, and environmental interferences improves the reliability of subsurface signals.
- In other engineering and sensing contexts, artifact rejection supports accurate monitoring of processes, safety systems, and quality control.
See, for example, electroencephalography workflows that incorporate ICA, regression, and wavelet denoising; magnetoencephalography pipelines that integrate artifact subtraction; and functional magnetic resonance imaging preprocessing that combines motion correction with data-driven artifact removal.
Controversies and debates
- Signal loss vs artifact removal: A central tension is between removing artifacts and preserving genuine signal. Overzealous rejection can discard meaningful neural activity or other informative content, leading to biased conclusions or reduced statistical power.
- Subjectivity and reproducibility: Manual artifact labeling introduces rater-dependent variance. Even automated methods rely on parameters and training data, which can affect replicability across studies and laboratories.
- Pipeline flexibility and analytical bias: The order and combination of preprocessing steps (e.g., filtering, artifact rejection, normalization) can materially affect results. Critics warn that flexible pipelines may enable “researcher degrees of freedom” that inflate false positives unless properly documented and preregistered.
- Cross-domain differences: What counts as an artifact and how aggressively to reject it varies by domain. For instance, artifacts in EEG/MEG may have different implications than motion-related distortions in fMRI, leading to divergent best practices and standards.
- Transparency and standards: The field has increasingly emphasized preregistration, standardized reporting, and open data sharing to improve trust and comparability. This includes sharing preprocessing scripts and parameter choices so others can reproduce artifact handling steps.
Best practices and standards
- Documentation and preregistration: Clear recording of the artifact rejection criteria, thresholds, and component labels supports reproducibility.
- Validation and sensitivity analyses: Reporting how results change under different rejection schemes helps assess the robustness of findings.
- Multimodal cross-checks: When possible, corroborating findings across independent data modalities (e.g., EEG and MEG, or EEG and fMRI) can mitigate concerns about artifacts driving results.
- Open science and data sharing: Publishing preprocessing pipelines, code, and datasets enhances transparency and allows independent replication.
- Quality-control reporting: Summaries of data retained after cleaning, the amount of data removed, and the rationale for exclusions help readers assess study reliability.
History and evolution
Artifact rejection has evolved from manual, observer-based practices to a suite of automated, model-driven techniques. Early EEG research relied on visual inspection and simple thresholds, with later decades introducing statistical and mathematical tools that could disentangle artifacts from brain signals. The rise of ICA-based approaches, more sophisticated time-frequency methods, and imaging-specific strategies has driven substantial improvements in data quality while also raising questions about over-cleaning and bias. The ongoing development of standardized pipelines and validation frameworks reflects a broader movement toward rigorous, reproducible science in data-intensive disciplines.